Overview
VAV (Variable Air Volume) Fume Hood System is an intelligent ventilation control solution for high-standard laboratories. It maintains constant safe face velocity automatically by real-time adjusting exhaust air volume according to sash opening height, effectively cuts air consumption and reduces air conditioning energy loss.
This system consists of fume hood body, VAV air valve, velocity sensor, PLC control panel and differential pressure linkage module. It fully complies with NFPA 45, ASHRAE 110 and local lab safety standards, and can be linked with central AHU, room pressure monitoring and waste gas treatment equipment to build an interlocked intelligent ventilation system.
Suitable for chemical synthesis labs, pharmaceutical R&D labs, university teaching labs and multi-unit connected lab zones, the system can be matched with all sizes of 1200/1500/1800mm standard fume hoods, and supports single hood independent control or multi-hood centralized group control.
The system can be configured with
VAV air volume regulating valve
Sash position velocity sensor
Touch screen PLC control panel Room differential pressure interlock module
Central building BMS communication module Explosion-proof variable frequency exhaust fan
Remote monitoring cloud platform
Over-temperature & gas leakage alarm unit
Suitable for
Pharmaceutical R&D laboratories
University chemical teaching labs
Multi-connected centralized lab zones High energy consumption long-term operation labs
Hazardous chemical synthesis labs GMP sterile testing laboratories
Overseas export high-standard labs
Specifications
|
Parameter Category |
Standard VAV System |
Customized VAV System |
|
Matching Fume Hood Size |
1200mm / 1500mm / 1800mm |
Custom non-standard width |
|
Design Face Velocity |
0.4–0.6 m/s constant stable |
0.3–0.8 m/s adjustable parameter |
|
Air Volume Adjustment Range |
150–1800 m³/h |
Wide range 100–2500 m³/h ultra-large air volume |
|
Control Mode |
Single independent control |
Group centralized BMS linkage control |
|
Communication Protocol |
Modbus-RTU |
Modbus TCP / Bacnet IP for building automation |
|
Power Supply |
AC220V 50Hz |
AC110V export version available |
|
Alarm Function |
Sash high open / low velocity alarm |
Over-temperature, gas leakage, fan fault multi-alarm |
|
Working Temperature |
10–40℃ |
Explosion-proof module for high solvent volatilization labs |
Materials & Options
Hardware & Handles
Color options
Configurations
Accessories
Gallery
Downloads
Quick Inquiry
Appointment Information
Navigation
Navigation
Contact Us
Phone: +86 400 6250 599
Telephone: +8619072311749
E-mail: info@yt-etcolabs.com
WhatsApp: +86 190 7231 1749
Address:Room 1110, Edenburg Mansion, No.139 Hengxi Road, Minhang District, Shanghai, China